The NEW Utility Control Centre
![]() |
![]() |
High Quality, Very competitive by design to:-
IEC 61439-1&2 (2009)
(BS EN 61439-1:2009 & BS EN 61439-2:2009)
For many years Rolla have been supplying the system/panel building industry with High Quality Motor Control Centres, many of which are an important part of the UK Water Companies Framework Agreements.
With cost savings firmly in mind we have drawn on our experience in this market sector and developed the new Utility Control Centre.
This highly competitive Motor Control Centre incorporates all the requirements of the water industry while maintaining the high quality of build that Rolla is renowned for.
Front Access or Rear Access, Form 4 Type 2 or 3
Click below for further details
|
|
Ratings from 400A to 2000A in standard size units.
Glossy Leaflet (PDF) (4MB) ![]()
Manufactured on state of the art CNC Machinery

Using Rolla's Unique KATTA (TM) Busbar Mounting System
Verified to Clause 10.2.3
Design Verification of Incoming Switches
Verified to Clause 10.11
![]() |
![]() |
| 50kA – 1250A ABB E2 ACB |
25kA - 400A ABB X1 ACB |
Tests include Phases, Neutrals and Earth Bars for 1 Second.
All tested at 50kA/25kA (Icw & Icc), including Rolla Neutral Links.
Previous tests included devices from Merlin Gerin (Schneider), Socomec and Siemens.
Design Verification of Outgoing Switches
Verified to Clause 10.11
400A
630A
800A |
![]() |
ABB OS400
ABB OS630
ABB OS800 |
All tested at 50kA Prospective (Icc), including Rolla Neutral Links
More details of the devices tested can be found on the ABB website
Latest Tests were carried out at ABB SACE Testing Laboratory, Bergamo, Italy

Previous tests included devices from Merlin Gerin (Schneider) and Socomec
Temperature Rise Verified
Verified to Clause 10.10
Impulse Test Verified Ui = 690VAC, Uimp = 8kV
Verified to Clauses 10.9.2 and 10.9.3.2
![]() |
![]() |
![]() |
| 5kV Voltage Tester | 12kV Impulse Generator (1,2/50µS) |
Digital Storage Oscilloscope (To view waveforms) |
All tests can be repeated as required in Rolla Laboratory
after incorporation of switching devices if necessary.
Full test reports provided.
Utility Framework Schedule Package
Design Verifications required based on Table D1
Item |
Description of Characteristic |
Clauses |
Verification |
1 |
Resistance to corrosion |
10.2.2 |
|
Resistance of insulating materials to normal heat |
10.2.3.2 | ||
Resistance to abnormal heat and fire due to internal electric effects |
10.2.3.3 | ||
Lifting |
10.2.5 | ||
2 |
Degree of protection of enclosures |
10.3 |
|
3 |
Clearance and creepage distances |
10.4 |
|
4 |
Effective continuity between the exposed conductive parts of the ASSEMBLY and the protective circuit |
10.5.2 |
|
| Effectiveness of the assembly for external faults | 10.5.3 | ||
5 |
Incorporation of switching devices and components |
10.6 |
Customer |
6 |
Internal electrical circuits and connections |
10.7 |
Customer |
7 |
Terminals for external conductors |
10.8 |
Customer |
8 |
Power-frequency withstand voltage |
10.9.2 |
|
| Impulse withstand voltage | 10.9.3 | ||
9 |
Temperature-rise limits |
10.10 |
|
10 |
Short-circuit withstand strength |
10.11 |
|
11 |
Electromagnetic compatibility (EMC) |
10.12 |
Customer |
12 |
Mechanical operation |
10.13 |
Customer |
For more information and full details, including ongoing technical support, please contact us.